[Switch Timing] Switch timing from leading edge to normal, plain paper 1
2422
(Paper Type, Edge) Paper Type -> N: Normal LE: Leading Edge
2422 002
T. Roll 2: N: LE
2422 003
Separation: N: LE
[Normal: [K]: TE] Transfer roller current and discharge plate voltage for the
trailing edge area, plain paper 1, black toner
2423
Paper side: 1st or 2nd
Unit -> T.Roll2: Transfer roller, Separation: Discharge plate (paper separation)
2423 003
Separation
2423 007
T. Roll 2: 1st
2423 012
T. Roll 2: 2nd
[Switch Timing] Switch timing from normal to trailing edge, plain paper 1
2424
(Paper Type, Edge) Paper Type -> N: Normal, Edge ->TE: Trailing Edge
2424 002
T. Roll 2: N: TE
2424 003
Separation: N: TE
[Normal: [FC]: LE] Transfer roller current and discharge plate voltage for the
leading edge area, plain paper 1, CMY toner
2426
Paper side: 1st or 2nd
2426 003
Separation
2426 007
T. Roll 2: 1st
2426 012
T. Roll 2: 2nd
[Normal: [FC]: TE] Transfer roller current and discharge plate voltage for the
2428
trailing edge area, plain paper 1, CMY toner
2428 003
Separation
2428 007
T. Roll 2: 1st
2428 012
T. Roll 2: 2nd
[Normal2: [K]] Transfer roller current and discharge plate voltage for the image
area, plain paper 2, black toner
(Process Speed, Paper Side, Unit) Process Speed -> RS: Regular speed,
2432
Paper Side: 1st or 2nd
Unit -> T.Roll2: Transfer roller, Separa.: Discharge plate (paper separation)
2432 007
RS: 1st: T. Roll 2
2432 008
RS: 1st: Separa.
2432 012
RS: 2nd: T. Roll 2
2432 013
RS: 2nd: Separa.
SM
CÓPIA NÃO CONTROLADA
*EGB
[0 to 200 / 10 / 1 mm/step]
*EGB
[0 to 200 / 25 / 1 mm/step]
*EGB
[0 to 400 / 100 / 5%/step]
*EGB
*EGB
*EGB
[0 to 200 / 10 / 1 mm/step]
*EGB
[0 to 200 / 30 / 1 mm/step]
*EGB
[0 to 400 / 100 / 5%/step]
*EGB
*EGB
*EGB
[0 to 400 / 100 / 5%/step]
*EGB
*EGB
*EGB
Adjusts the transfer roller current.
[0 to 60 / 20.0 / 0.1 -µA/step]
*EGB
Adjusts the discharge plate voltage.
[0 to 4 / 2.0 / 0.1 -KV/step]
*EGB
[0 to 60 / 10.0 / 0.1 -µA/step]
*EGB
[0 to 4 / 2.0 / 0.1 -KV/step]