Ricoh G104 Service Manual page 178

G104; g160; g161
Table of Contents

Advertisement

ENGINE SERVICE MODE
5816 010
RCG Read Timeout
5816 011
Port 80 Enable
5821
[Remote Service Address]
5821 001
CSS-PI Device Co
5821 002
RCG IP Address
5824
[NV-RAM Data Upload]
5824 001
5825
[NV-RAM Data Download]
5825 001
5828
[Network] Job spool settings/ Interface selection for Ethernet and wireless LAN
5828 050
1284 Compatible
5828 052
ECP
5828 065
Job Spool
5828 066
HD job Clear
G104
CÓPIA NÃO CONTROLADA
*CTL
Sets the timeout counter for reading
processing.
[0 to 100 / 60 / 1 second/step]
*CTL
Enables or disables access to the SOAP
method via port 80.
[0 to 1 / 0 / 1/step]
0: Disables, 1: Enables
*CTL
[0 to 4 / 0 / 1/step] DFU
*CTL
Sets the IP address of the RCG (Remote
Communication Gate).
[00000000h to FFFFFFFFh / 00000000h /
1/step]
#
Uploads the UP and SP mode data (except
for counters and the serial number) from the
NVRAM to an SD card.
#
Downloads the UP and SP mode data from
an SD card to the NVRAM.
*CTL
Switches Centronics IEEE1284 compatibility
on/off for the network.
[ 0 or 1 / 1 / - ]
0: Disabled, 1: Enabled
NOTE: Selecting "0" disables bi-directional
*CTL
Switches the ECP setting for Centronics
off/on.
[0 or 1 / 1 / -]
0: Disabled, 1: Enabled
NOTE: With "1" selected, SP5-828-050
*CTL
Switches the job spool on/off.
[0 or 1 / 0 / -]
0: Disabled, 1: Enabled
*CTL
Selects the treatment of the job when a
spooled job exists at power on.
[0 to 1 / 1 / 1/step]
0: Data is cleared, 1: Automatically printed
5-62
CÓPIA NÃO CONTROLADA
data transmission.
must be enabled for 1284 mode
compatibility.
SM

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

G160G161

Table of Contents