Ricoh G104 Service Manual page 480

G104; g160; g161
Table of Contents

Advertisement

Service Mode Table
For example: 3500010 (EU default)
The timer is advanced by 1 hour at am 0:00 on the 5th Sunday in March
The digits are counted from the left.
Make sure that SP5-307-1 is set to "1".
5307 004
Rule Set(End)
Specifies the end setting for the summer time mode.
There are 8 digits in this SP.
1st and 2nd digits: The month. [1 to 12]
3rd digit: The week of the month. [0 to 5]
4th digit: The day of the week. [0 to 6 = Sunday to Saturday]
5th and 6th digits: The hour. [00 to 23]
The 7th and 8 digits must be set to "00".
The digits are counted from the left.
Make sure that SP5-307-1 is set to "1".
5401
[Access Control]
5401 200 SDK1 Unique ID
5401 201 SDK1 Certification
Method
5401 210 SDK2 Unique ID
5401 211 SDK2 Certification
Method
5401 220 SDK3 Unique ID
5401 221 SDK3 Certification
Method
5404
[User Code Clear] User Code Counter Clear
5404 001
User Code Clear]
5501
[PM Alarm Interval] PM Alarm Interval
5501 001
Printout
G160/G161
CÓPIA NÃO CONTROLADA
NA: 105(4)60000, EU: 105(4)00000,
-
ASIA: 03100000
*CTL
"SDK" is the "Software Development Kit".
These data can be converted from SAS
*CTL
(VAS) when installed or uninstalled. DFU
*CTL
*CTL
*CTL
*CTL
-
Clears all counters for users.
Sets the PM alarm Interval. [0 to 9999 / 0 / 1k
prints/step]
*CTL
The alert is sent to the e-mail address that is
specified for the system administrator using a
5-100
CÓPIA NÃO CONTROLADA
SM

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

G160G161

Table of Contents