7803 017
R: PCU: [K]
7803 018
R: PCU: [M]
7803 019
R: PCU: [C]
7803 020
R: PCU: [Y]
7803 025
R: Trans Belt Unit
7803 026
R: T. Roll 2
7803 027
R: Fusing Unit
7803 033
Toner Supply: [K]
7803 034
Toner Supply: [M]
7803 035
Toner Supply: [C]
7803 036
Toner Supply: [Y]
7803 037
R%: PCU: [K]
7803 038
R%: PCU: [M]
7803 039
R%: PCU: [C]
7803 040
R%: PCU: [Y]
7803 045
R%: Trans Belt Unit
7803 046
R%: T. Roll 2
7803 047
R%: Fusing Unit
7804
[PM Count. Reset] Preventive Maintenance Counter Reset
(Sheets, Unit, [Color]) Trans Belt Unit: Transfer Belt Unit, T. Roll 2: Transfer
Roller 2, Waste Toner: Waste Toner Bottle, Toner: Toner Bottles
Clears the PM counter for each unit.
7804 002
PCU: [K]
7804 003
PCU: [M]
7804 004
PCU: [C]
7804 005
PCU: [Y]
7804 009
Trans Belt Unit
7804 010
Transfer Roller 2
7804 011
Fusing Unit
7804 012
S: By-pass
7804 013
S: Tray 1
7804 014
S: Tray 2
7804 015
S: Tray 3
7804 017
S: Toner: [K]
7804 018
S: Toner: [M]
SM
CÓPIA NÃO CONTROLADA
*EGB
Displays the number of revolutions of motors
or clutches for each current maintenance
*EGB
unit.
*EGB
[0 to 9999999 / 0 / 1 revolution/step]
*EGB
When a unit is replaced, the machine
*EGB
automatically detects that the new unit is
*EGB
installed. Then, the current PM counter value
*EGB
is automatically moved to the PM Counter -
Previous (SP7-906-11 to 20) and is reset to
"0". The total number of revolutions made
with the last unit replaced can be checked
with SP7-906-11 to 20.
[0 to 9999999 / 0 / 1 rotation/step]
*EGB
Displays the number of sheets printed until
the waste toner bottle becomes full or toner
*EGB
runs out.
*EGB
[0 to 9999999 / 0 / 1 /step]
*EGB
*EGB
Displays the value given by the following
formula:
*EGB
(Current revolution ÷ Target revolution) ×
*EGB
100, where "Current revolution" is the current
*EGB
value for the counter of the part, and "Target
*EGB
revolution" is the values of SP7-803-17
*EGB
through 27. This shows how much of the
*EGB
unit's expected lifetime has been used up.
The R% counter is based on rotations, not
prints. If the number of rotations reaches the
limit, the machine enters the end condition
for that unit. If the print count lifetime is
reached first, the machine also enters the
end condition, even though the R% counter
is still less than 100%.
[0 to 999 / 0 / 1 rotation%/step]
-
Clears the PM counter.
-
Press the Enter key after the machine asks
"Execute?".
-
When a unit is replaced, the machine
-
automatically detects that the new unit is
-
installed. Then, the current PM counter value
-
is automatically moved to the PM Counter-
-
Previous (SP7-906-1 to 40) and is reset to
-
"0".
-
-
-
-
-
5-73