2306
[Vd Link Corre.] Vd Link Correction
2306 001
Setting
2306 002
Correction Coef.
2314
[Trans.Belt Bias] Transfer Belt Current at Process Control
2314 011
Process Cont. [K]
2314 012
Process Cont. [M]
2314 013
Process Cont. [C]
2314 014
Process Cont. [Y]
[T.Roll2 Clean.] Transfer Roller Cleaning
2326
(Positive or Negative Bias, Process Speed) Process Speed -> RS: Regular
speed, LS: Low speed
2326 002
Posi. Bias: RS
2326 003
Posi. Bias: LS
2326 005
Nega. Bias: RS
2326 006
Nega. Bias: LS
[Trans.Belt Bias] Transfer Belt Current
2352
([Color], Process Speed) Process Speed -> RS: Regular speed
2352 001
[K]: RS
2353
[Trans.Belt Bias] Transfer Belt Current
SM
CÓPIA NÃO CONTROLADA
Sets the Vd link correction.
*EGB
[0 or 1 / 0 / -] Alphanumeric
0: Execute, 1: Not execute
Adjusts the Vd link correction coefficient.
*EGB
[1.00 to 2.50 / 1.00 / 0.01/step]
Adjusts the transfer belt current at process
*EGB
control for [K].
[0 to 60 / P2a 15.0, P2b: 13.0 / 0.1 µA /step]
*EGB
Adjusts the transfer belt current at process
control for [M, C].
*EGB
[0 to 60 / P2a 12.5, P2b: 10.0 / 0.1 µA /step]
Adjusts the transfer belt current at process
*EGB
control for [Y].
[0 to 60 / P2a 12.5, P2b: 13.0 / 0.1 µA /step]
*EGB
Adjusts the positive voltage for transfer roller
cleaning.
*EGB
[0 to 2 / 2.0 / 0.1 KV/step]
*EGB
Adjusts the negative voltage for transfer
roller cleaning.
*EGB
[0 to 60 / 60.0 / 0.1V/step]
Adjusts the current that is applied to the
transfer belt.
[0 to 60 / P2a 15.0, P2b: 17.0 / 0.1 µA /step]
5-43
CÓPIA NÃO CONTROLADA
Service Mode Table
G160/G161

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

G160G161

Table of Contents