1004 079
DEV / OPC [K]: LS:
OHP
1004 080
DEV [CMY]: LS: OHP
1004 081
OPC [CMY]: LS: OHP
1004 082
Fusing: LS: OHP
1004 083
T.Belt: LS: OHP
1004 084
PFU: LS: OHP
1004 085
Duplex: LS: OHP
1006
[Phase Adjust.] Phase Adjustment
1006 001
Angle
1104
[Fusing Cont.] Fusing Control
1104 001
Control Method
Selects the fusing control method.
0: ON/OFF Control 1: PID Control (Phase control)
1104 022
Max. Wait Time
Adjusts the maximum waiting time for the target printing temperature of fusing
unit. After this interval, printing will start if the temperature did not get to the
target.
1104 023
Paper Feed. Temp.
Adjusts the increase in the temperature of the fusing unit between the ready
condition and the start of paper feed at the start of a new job.
1104 024
1st Add Time: LS
For print jobs at low speed. If the interval between jobs is less than this setting,
then the temperature change (1104 025) for the first page of a new job is not
applied.
1104 025
1st Add Temp.
Adds this value to the basic fusing temperature, for the first page of a new job.
This extra temperature is necessary because when the printer starts the first
page, the fusing unit is not warm enough.
1104 026
1st Temp. Maint.
Adjusts the time for maintaining the temperature change that is set with 1104
025.
1104 027
1st Print Inter.
For print jobs at regular speed. If the interval between jobs is less than this
setting, then the temperature change (1104 025) for the first page of a new job
is not applied.
SM
CÓPIA NÃO CONTROLADA
*EGB
Adjusts the black development and OPC
motor speed.
[-4.00 to 4.00 / -1.35 / 0.01 %/step]
*EGB
Adjusts the color development motor speed.
[-4.00 to 4.00 / 0.0 / 0.01%/step]
*EGB
Adjusts the color OPC motor speed.
[-4.00 to 4.00 / -1.35 / 0.01%/step]
*EGB
Adjusts the paper exit and fusing motor
speed.
[-4.00 to 4.00 / 0.6 / 0.01%/step]
*EGB
Adjusts the transfer belt motor speed.
[-4.00 to 4.00 / 0.0 / 0.01%/step]
*EGB
Adjusts the speed of the feed motor in the
optional paper tray unit.
[-4.00 to 4.00 / -1.14 / 0.01%/step]
*EGB
Adjusts the duplex motor speed.
[-4.00 to 4.00 / -0.36 / 0.01%/step]
*EGB
Adjusts the phase angle between the K drum
and the CMY drums.
[-180 to 180 / 0 / 1°/step]
*EGB
[0 or 1 / 1 / -] Alphanumeric
*EGB
[0 to 255 / 30 / 1 sec/step]
*EGB
[0 to 30 / 5 / 1°/step]
[0 to 50 / 0 / 0.1 sec/step]
*EGB
[0 to 20 / 0 / 1°C/step]
*EGB
[0 to 50 / 0 / 1 sec/step]
*EGB
[0 to 100 / 0.2 / 0.1 sec/step]