[OHP: [K]: LE] Transfer roller current and discharge plate voltage correction
2621
for the leading edge area of OHP in B/W mode
2621 002
Transfer Roller2
2621 003
Separation
[Switch Timing] Switch timing from leading edge to normal, OHP
2622
(Paper Type, Edge) Paper Type -> OHP, LE: Leading Edge
2622 002
T. Roll 2: OHP: LE
2622 003
Separa.: OHP: LE
[OHP: [K]: TE] Transfer roller current and discharge plate voltage correction
2623
for the trailing edge area of OHP in B/W mode
2623 002
Transfer Roller2
2623 003
Separation
[Switch Timing] Switch timing from normal to trailing edge, OHP
2624
(Paper Type, Edge) Paper Type -> OHP, TE: Trailing Edge
2624 002
T. Roll 2: OHP: TE
2624 003
Separa.: OHP: TE
[OHP: [FC]: LE] Transfer roller current and discharge plate voltage correction
2626
for the leading edge area of OHP in color mode
2626 002
Transfer Roller2
2626 003
Separation
[OHP: [FC]: TE] Transfer roller current and discharge plate voltage correction
2628
for the trailing edge area of OHP in B/W mode
2628 002
Transfer Roller2
SM
CÓPIA NÃO CONTROLADA
*EGB
[0 to 400 / 100 / 5%/step]
The value displayed on the LCD is different
from these SP's values. For example, "20%"
*EGB
on the LCD actually means 100%.
*EGB
[0 to 200 / 10 / 1 mm/step]
*EGB
[0 to 200 / 25 / 1 mm/step]
*EGB
[0 to 400 / 100 / 5%/step]
The value displayed on the LCD is different
from these SP's values. For example, "20%"
*EGB
on the LCD actually means 100%.
*EGB
[0 to 200 / 10 / 1 mm/step]
*EGB
[0 to 200 / 30 / 1 mm/step]
*EGB
[0 to 400 / 100 / 5%/step]
The value displayed on the LCD is different
from these SP's values. For example, "20%"
*EGB
on the LCD actually means 100%.
*EGB
[0 to 400 / 100 / 5%/step]