Junos Pulse Gateway Electrical and Power Requirements
Related
Documentation
Copyright © 2014, Juniper Networks, Inc.
NOTE:
Install the device only in restricted areas, such as dedicated equipment
rooms and equipment closets, in accordance with Articles 110–16, 110–17,
and 110–18 of the National Electrical Code, ANSI/NFPA 70.
Clearance Requirements for Airflow in and Hardware Maintenance of the Junos Pulse
Gateway on page 33
There are factors you must consider while planning the electrical wiring and power
availability at your site. These factors include the following:
Power specifications and requirements for the device
Electrical wiring guidelines for the device installation site
Power, connection, and power cord specifications for the device
Grounding guidelines and specifications for the device
The power requirements vary greatly depending upon your configuration. Use the following
AC power specifications as a general rule.
Table 19: Power Specifications for an AC Power Supply Used in the MAG
Series Junos Pulse Gateway
Item
MAG2600
AC input
Operating
voltage
range—100
through 240
VAC
AC input line
50 through 60
frequency
Hz
AC input
1 A
current rating
AC output
30-W
power
Type
External brick
power supply
AC Power Cord Specifications for the MAG6610 and MAG6611 Junos Pulse Gateway
on page 35
MAG4610
MAG4611
Operating
Operating
range—100
range—100
through 240
through 240
VAC
VAC
50 through
50 through
60 Hz
60 Hz
1 A
1 A
70-W
70-W
Fixed
Fixed
Chapter 4: Site Preparation
MAG6610
MAG6611
Operating
Operating
range—100
range—100
through 240
through 240
VAC
VAC
50 through 60
50 through 60
Hz
Hz
8 A
10 A
560-W
750-W
Modular
Modular
(removable)
(removable)
29