Maintenance Objects
Link Status Test (#601)
This non-destructive test determines the state of the call control signaling link for
VALs. If the signaling link is physically connected, the test sends a test frame over
the link and checks for a response. The test passes only if both the signaling link
is connected and the test frame is successfully transmitted.
A failure can indicate a problem with:
this circuit pack.
the packet bus.
the packet interface circuit pack.
Table 557. TEST #601 Link Status Test
Error
Test
Code
Result
Description/ Recommendation
1125
ABORT
RSCL link or VAL board not in service.
Release the board.
Repeat the test.
Escalate if the problem persists.
2012
ABORT
Could not allocate the necessary system resources to run this test.
2100
ABORT
Internal system error.
Retry command at 1-minute intervals, up to 5 times.
If the problem persists, escalate the problem.
2
FAIL
The RSCL control link disconnected.
Retry command at 1-minute intervals, up to 5 times.
If the test continues to fail, execute the Packet Interface Test (#598) (test
board UUCSS) to see if the problem is in the circuit pack.
If the Packet Interface Test (#598) fails, refer to Packet Interface Test repair
procedures.
If the Packet Interface Test (#598) passes, refer to Packet Control Circuit
Pack and Packet Bus repair procedures.
3
FAIL
Received no response to RSCL control link test frame.
Retry command at 1-minute intervals, up to 5 times.
If the problem persists, reset the circuit pack (reset board UUCSS).
If test continues to fail, replace the circuit pack.
PASS
RSCL control link connected.