Avaya DEFINITY Server CSI Maintenance Manual page 1908

Table of Contents

Advertisement

Maintenance Objects
Table 574. TEST #6 NPE Crosstalk Test — Continued
Error
Test
Code
Result
1002
ABORT
1003
ABORT
1004
ABORT
1020
ABORT
2000
ABORT
2100
ABORT
FAIL
PASS
1908
Issue 5 October 2002
Description/ Recommendation
The system could not allocate time slots for the test. The system may be
under heavy traffic conditions, or it may have time slots that are
out-of-service due to TDM-BUS errors. The status health command can be
used to determine if the system is experiencing heavy traffic. Refer to
TDM-BUS Maintenance documentation to diagnose any active TDM-BUS
errors.
1. If system has no TDM-BUS errors, and if it is not handling heavy traffic,
repeat the test at 1-minute intervals a maximum of 5 times.
The system could not allocate a tone receiver for the test. The system may
be oversized for the number of Tone Detectors present, or some Tone
Detectors may be out-of-service. The list measurement tone-receiver
command displays information on the system's tone receivers.
1. Look for TTR-LEV errors in the Error Log. If errors are present, refer to
TTR-LEV Maintenance documentation.
2. Look for TONE-PT errors in the Error Log. If errors are present, refer to
TONE-PT Maintenance documentation.
3. If neither condition exists, retry the test at 1-minute intervals a
maximum of 5 times.
The port has been seized by a user for a valid call. Use the status
access-endpoint <extension> command to determine when the port is
available for testing. The port is available when it is in the in-service/idle
state.
1. Retry the command at 1-minute intervals a maximum of 5 times.
The test did not run due either to a previously existing error on the specific
port or to a more general circuit pack error.
1. Examine the Error Log for existing errors against this port or the circuit
pack, and attempt to diagnose the already existing error.
Response to the test request was not received within the allowable time
period.
System resources required for this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5 times.
The NPE of the tested port was found to be transmitting in error. This
causes noisy and unreliable connections.
1. Replace the circuit pack.
The port is correctly using its allocated time slots.
1. User-reported troubles on this port should be investigated by using
other port tests and by examining the terminal adapter or the external
wiring.
Continued on next page