PIAGGIO MP3 530 hpe Service Station Manual page 257

Hide thumbs Also See for MP3 530 hpe:
Table of Contents

Advertisement

Machine Translated by Google
Cooling system
To vent the system when filling the circuit, there is a be. on the upper part of the cylinder head
A special connection is provided (see filling instructions).
A cooling fan is required to ensure adequate cooling even when there is no wind
provided, which is controlled via the injection system.
Capacity of the cooling system
Recommended coolant
Turning on the cooling fan
Turning off the cooling fan
COOL - 260
TECHNICAL SPECIFICATIONS
Technical information
sealing pressure
Technical information
Opening start type
COOLING FAN
Technical information
Type
WATER PUMP
Technical information
Type
steering
Technical information
Type
EXPANSION VESSEL
Technical information
calibration
50% mixture of water and liquid for closed ones
Closure calibrated to 0.9 bar
THERMOSTAT
with wax and branching
Coaxial to the countershaft
COOLER
Made of aluminum, with horizontal circulation
Self-venting, parallel to the radiator
MP3 530 hpe
Description/Value
1,8 Liter
Circuits
Description/Value
95 ± 2°C
Description/Value
With piston
107°C
103°C
Description/Value
centrifugal force
Description/Value
Description/Value

Advertisement

Table of Contents
loading