MP3 530 hpe
- The distance between the outer rotor and the pump
Measure the pen housing (see illustration).
Technical specifications
Max. allowable clearance:
0,25 mm
- The axial play of the rotors with a ground
a measuring stick as a reference plane as in the figure
Check the information shown.
Technical specifications
Permissible limit:
0,1 mm
Installation
- Make sure the seal is correctly attached
is brought.
ANNOTATION
THE GASKET GEARS MUST BE FITTED IN THE
APPROPRIATE SEAT.
- Lubricate the internal rotors.
- Check that the pump cover is not off
used or scratched.
- Are different values measured or
Scratches or wear are found, the
Pump needs to be replaced.
- Attach the pump cover so that the drill
The rungs for attaching the fastening screws to the
housing are aligned with one another.
- Tighten the two fastening screws to the specified
torque.
Motor