6. Rotate the small FMS knob to display the drop down menu. Rotate the large FMS knob
to highlight the installed GDL 59 configuration. Press ENT key on PFD1.
7. Press the CHK All softkey.
8. Press the Load softkey.
9. Monitor load progress. Verify software load completes without errors as indicated by the
following:
Green "PASS" in the Configuration and Software columns for each item loaded.
"Upload Complete.............COMPLETE" in the summary box.
10. Press ENT key on PFD1 to acknowledge upload complete.
11. Deactivate cursor.
12. Scroll to the Configuration Manager page.
13. Press the CNFM CFG softkey.
14. Select ok when prompted to "Confirm configuration as expected configuration"
15. Power cycle the system. Verify there are no red-Xs or system alerts.
16. If red-Xs or system alerts are present, troubleshoot as necessary using Section 5.
17. If there are no red-Xs or system alerts, continue to Section 7.18.3.
Activation of Garmin Connext
In order to activate the optional GDL 59 and optional GSR 56 for Garmin Connext, contact
Garmin Product Support at one of the following numbers (M-F, 7:00 a.m. to 7:00 p.m. Central
Standard Time, - Central USA):
1.866.739.5687 (toll free in USA)
+1.913.440.1135 (worldwide)
Have the following information ready prior to calling:
If activating services for a GDL 59 installation
o Aircraft tail number, serial number, manufacturer, and model
o GDL 59 serial number
o G1000 system ID number
Garmin Product Support will provide additional information for activation of data services.
To obtain the G1000 system ID number and unit serial numbers, accomplish the following:
1. Turn the large FMS knob on the MFD to select the AUX page group.
2. Turn the small FMS knob to select the SYSTEM STATUS page. Record the SYSTEM ID
number shown in the AIRFRAME field. This number is unique for each G1000 system.
3. Press the LRU softkey to activate the cursor in the LRU INFO field. Use the large FMS
knob to scroll the cursor to GDL 59. Record the GDL 59 serial number shown in the LRU
INFO field.