right/left and up/down localizer/glideslope signals using the test equipment. Verify that
the Flight Director and flight controls respond appropriately.
10. Couple FD to PFD1 by pressing the XFR button on the AFCS mode controller. Verify FD
is coupled to PFD1 as indicated by a left pointing arrow on the AFCS mode controller
next to the XFR button.
11. Repeat step 9 while coupled to PFD1.
12. If no other service is to be performed, continue to the return-to-service checks in Section
9.
G1000 NXi System Maintenance Manual
King Air 300 Series
190-00716-N1
Page 279