Key Alerts
Failure Message
MFD1 "key" KEYSTK – key is
stuck.
PFD 1 "key" KEYSTK – key is
stuck.
PFD 2 "key" KEYSTK – key is
stuck.
Miscellaneous Alerts
Failure Message
XTALK ERROR – A flight display
cross talk error has occurred.
DATA LOST – Pilot stored data
lost. Recheck settings.
G1000 NXi System Maintenance Manual
King Air 300 Series
190-00716-N1
Cause
The SYSTEM has determined a
key is stuck on MFD1.
The system has determined a key
is stuck on the PFD 1.
The system has determined a key
is stuck on the PFD 2.
Cause
A communication error has
occurred between the MFD and/or
PFDs.
Pilot stored data has been lost.
Solution
Go to the GDU TEST page in
configuration mode and verify key
is stuck (if key is stuck the
corresponding indicator will be
green).
Exercise suspected stuck key and
reset GDU TEST page to see if
indicator remains green without
pressing the key.
If problem persists replace the
display.
Solution
Ensure a database error has not
occurred (identified in the ALERTS
window on the PFD).
If a database error has
occurred, correct error before
proceeding.
Check display Ethernet
interconnect wiring.
Replace PFD1 with a known good
unit, to verify location of problem:
If problem persists, reinstall
original PFD1 and replace
PFD2.
If problem persists, reinstall
PFD2 and replace MFD.
If the CLR key was held during a
power cycle, disregard message.
Cycle power to PFD1:
Ensure CLR key is not stuck
on the GDU TEST page.
If problem persists, replace
PFD1.
Page 188
Revision 1