5. Activate cursor and rotate the small FMS knob to display the drop down menu. Rotate
the large FMS knob to highlight "01) Baseline" and press ENT key on PFD1.
6. Rotate the small FMS knob to display the drop down menu. Rotate the large FMS knob
to highlight King Air 200-300 Series Baseline Load. Press ENT key on PFD1.
7. Press the CLR ALL key.
8. Scroll to highlight GMC.
9. Highlight the software box and press the ENT key to check the box.
10. Highlight the Configuration box and press the ENT key to check the box.
11. Press the Load softkey.
12. Monitor load progress. Verify software load completes without errors as indicated by the
following:
Green "PASS" in the Configuration and Software columns for each item loaded.
"Upload Complete.............COMPLETE" in the summary box.
13. Press ENT key on PFD1 to acknowledge upload complete.
14. Deactivate cursor.
15. Scroll to the Configuration Manager page.
16. Press the CNFM CFG softkey.
17. Select ok when prompted to "Confirm configuration as expected configuration"
18. Power cycle the system. Verify there are no red-Xs or system alerts.
19. If red-Xs or system alerts are present, troubleshoot as necessary using Section 5.
20. If there are no red-Xs or system alerts, continue to Section 7.13.3.
GCU 477 Test
Perform the following key and knob presses and knob rotations on the GCU 477, and verify the
actions on the MFD.
1. Rotate the large FMS knob and verify that the page groups change.
2. Rotate the small FMS knob and verify that the pages change within the page groups.
3. Use the large FMS knob to display the Map page group and the small FMS knob to
display the Map - Navigation Map page.
4. Rotate the RANGE knob to the right and verify the map display zooms out.
5. Rotate the RANGE knob to the left and verify the map display zooms in.
6. Press the RANGE knob to get the pointer on the map display.
7. Move the RANGE knob to the left and verify the pointer moves to the left.
8. Move the pointer up, right and down and verify that the pointer moves accordingly.
9. Press the RANGE knob to stop displaying the pointer.
10. Press the left and right arrowheads of the SOFTKEY SELECT keys. Verify softkeys
highlighting on the MFD changes.
11. Press the SEL key to select one of the softkeys.