The PRODUCT window displays information regarding each G1000 LRU. The
LRU column depicts the reported software version of the LRU (may be blank if
PFD1 cannot communicate with the unit yet until after config files are loaded).
The CARD VERS column shows the LRU software version stored on the Loader
Card.
The SOFTWARE column may or may not have all boxes checked automatically.
For the initial software load in the system all software boxes should be checked
to load all files. This is done by pressing the CHK ALL softkey when instructed
below.
The CONFIGURATION column defaults to having all unit configuration boxes
checked.
The hardware serial number is used to determine appropriate software for the
GIA COM, GIA NAV, GMU 44, and GSA 8X units. Until the system
configuration loads sufficiently to access and read these units, they may show a
"INV" invalid status under the LRU VERS and CARD VERS columns with up to
two line items per item (representing different hardware configurations). After
the configuration files are loaded, the units will update and remove the "INV"
status and will load automatically.
5. Press the CHK All softkey.
6. Press the Load softkey.
Monitor the loading progress and verify the software load completes without errors as
indicated by the following:
Green "PASS" or White "N/A" in all Configuration and Software columns.
"Upload Complete.............COMPLETE" in the summary box.
7. Press the ENT key to acknowledge the "Upload Complete" box.
03) 300 Series Engine-Prop Software and Configuration Load
Follow this procedure to configure the airframe type.
1. Move the cursor to the Group window and rotate FMS inner knob to display drop down
menu. Highlight "03) 300 Series Engine-Prop" and press the ENT key to select it.
2. The cursor should automatically move to the ITEM window. Rotate the small FMS knob
to highlight the appropriate airframe, engine, and prop combination that was checked on
the Configuration checklist in Section 3.6, in the 03) 300 Series Engine-Prop checklist
group and press the ENT key to select it.
3. Press the CHK All softkey.
4. In the PRODUCT window, move the cyan selection box down with the large FMS knob
to highlight the "CARD COPY" configuration check box. Press the ENT key to uncheck
the configuration check box.
5. Press the Load softkey.