Gsm 86 Slip Clutch Torque Check Procedure; Figure 4-3, Gfc Status Page - Garmin G1000 Nxi System Maintenance Manual

Hide thumbs Also See for G1000 Nxi:
Table of Contents

Advertisement

GSM 86 Slip Clutch Torque Check Procedure

Perform the test per Sections 4.9.1 (preferred) or 4.9.2. To perform the procedure, all G1000
system equipment must be installed and operational.
Automated Slip Clutch Test Procedure
1. Before starting test, select the AVIONICS MASTER PWR, EXT PWR, and BATT
switches to OFF.
2. Press and hold the ENT key on PFD1 while selecting the AVIONICS MASTER PWR,
EXT PWR, and BATT switches to ON.
3. Release the ENT key after 'INITIALIZING SYSTEM' appears in the upper left corner of
PFD1.
(Steps 1 through 3 put PFD1 in Configuration Mode and PFD2 / MFD in normal mode.)
4. With the MFD in Normal Mode, press the red DISPLAY BACKUP button on the pilot's
GMA audio panel to place the MFD in reversion mode.
5. With PFD1 in Configuration Mode, go to the GFC Page Group and select the GFC
STATUS page using the FMS knobs.
It is highly recommended that the following test be performed at
temperatures between 50° F and 120° F.
6. Use GIA 1 in the SELECT GIA UNIT field for these tests. Use the FMS knob to select
the desired servo (Pitch, Roll, Yaw or Pitch Trim).
7. Verify that the Monitor Board and Control Board PFT status fields show PASSED.
G1000 NXi System Maintenance Manual
King Air 300 Series
190-00716-N1

Figure 4-3, GFC Status Page

IMPORTANT!
Page 119
Revision 1

Hide quick links: