4. In the PRODUCT window, move the cyan selection box down with the large FMS knob
to highlight the "CARD COPY" configuration check box. Press the ENT key to uncheck
the configuration check box.
5. Press the Load softkey.
6. Monitor the loading progress and verify the software load completes without errors as
indicated by the following:
Green "PASS" in the Configuration and Software columns for each item loaded.
"Upload Complete.............COMPLETE" in the summary box.
7. Press the ENT key to acknowledge the "Upload Complete" box.
8. Rotate the large FMS knob to highlight the ITEM window and select the second file on
the Configuration checklist. Repeat steps 2-7 to load the second file.
06) Garmin Transponders Software and Configuration Load
Follow this procedure to configure the Garmin transponders.
1. Rotate the large FMS knob until the Group field is highlighted, rotate the small FMS knob
to activate the drop down menu. Rotate the small FMS knob and select "06) Garmin
Transponders" and press the ENT key to select it.
2. In the ITEM window, rotate the small FMS knob to highlight the item that was checked
on the Configuration checklist in Section 3.6 in the 06) Garmin Transponders checklist
group and press the ENT key to select it.
3. Press the CHK All softkey.
4. In the PRODUCT window, move the cyan selection box down with the large FMS knob
to highlight the "CARD COPY" configuration check box. Press the ENT key to uncheck
the configuration check box.
5. Press the Load softkey.
6. Monitor the loading progress and verify the software load completes without errors as
indicated by the following:
Green "PASS" in the Configuration and Software columns for each item loaded.
"Upload Complete.............COMPLETE" in the summary box.
7. Press the ENT key to acknowledge the "Upload Complete" box.
07) Connext –SXM Software and Configuration Load
Follow this procedure to configure FS 510, GDL69A, GDL59, and GSR 56 options if installed.
1. Rotate the large FMS knob until the Group field is highlighted, rotate the small FMS knob
to activate the drop down menu. Rotate the small FMS knob and select "07) Connext -
SXM" and press the ENT key to select it.
2. In the ITEM window, rotate the small FMS knob to highlight the first item that was
checked on the Configuration checklist in Section 3.6 in the 07) Connext - SXM checklist
group and press the ENT key to select it.
3. Press the CHK All softkey.
G1000 NXi System Maintenance Manual
King Air 300 Series
190-00716-N1
Page 72
Revision 1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents