Cooling Alerts
Failure Message
MFD1 COOLING – has poor
cooling. Reducing power usage.
PFD 1 COOLING – has poor
cooling. Reducing power usage.
PFD 2 COOLING – has poor
cooling. Reducing power usage.
G1000 NXi System Maintenance Manual
King Air 300 Series
190-00716-N1
Cause
MFD1 has exceeded its operating
temperature range.
PFD 1 has exceeded its operating
temperature range.
PFD 2 has exceeded its operating
temperature range.
Solution
Check cooling fan and wiring for
proper operation (if applicable).
Replace cooling fan if unable
to determine if operating
correctly.
If problem persists, replace the
MFD.
If problem continues contact
Garmin Aviation Product Support
for assistance.
Check cooling fan and wiring for
proper operation (if applicable).
Replace cooling fan if unable
to determine if operating
correctly.
If problem persists, replace the
PFD1.
If problem continues contact
Garmin Aviation Product Support
for assistance.
Check cooling fan and wiring for
proper operation (if applicable).
Replace cooling fan if unable
to determine if operating
correctly.
If problem persists, replace the
PFD2.
If problem continues contact
Garmin Aviation Product Support
for assistance.