Table 5-5, Magnetometer Interference Test Sequence - Garmin G1000 Nxi System Maintenance Manual

Hide thumbs Also See for G1000 Nxi:
Table of Contents

Advertisement

rd
The 3
item on the checklist instructs the operator to "prepare a detailed test
sequence with precise start and stop times for exercising all electronic devices".
The list of relevant electronic devices are given in Table 5-5. Begin test with flaps
retracted, flight controls in a neutral position, all lights selected OFF.
Elapsed Time since Start of Test
(min:secs)
0:00
0:05
0:10
0:20
0:30
0:40
0:50
1:00
1:20
1:40
1:50
2:00
2:10
2:20
2:30
2:40
2:50
3:00
3:10
3:20
3:30
3:40
3:50
4:00

Table 5-5, Magnetometer Interference Test Sequence

6. When the CALIBRATE field is blinking, press the ENT key to begin the procedure, and
have a stopwatch ready to begin recording the elapsed time.
It is important that the "time equals zero" moment corresponds with the
moment the PFD first displays the blinking TEST COMPLETE? Message.
G1000 NXi System Maintenance Manual
King Air 300 Series
190-00716-N1
NOTE
Action
Test begins
Tail Flood lights on
Tail Flood lights off
Navigation lights on
Navigation lights off
Landing lights on
Landing lights off
Taxi lights on
Taxi lights off
Strobes on
Strobes off
Recognition lights on
Recognition lights off
Beacon on
Beacon off
Rudder full left
Rudder full right
Rudder Trim full left
Rudder Trim full right
Elevator full nose UP
Elevator full nose DN
Elevator trim full nose UP
(manual electric)
Elevator trim full nose DN
(manual electric)
End of test
NOTE
Page 207
Revision 1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents