RVSM Static Port Height Inspection
The Gauging Assembly p/n SPF-4 (A1M-BCH-GE) is available from Beechcraft. Any alternate
tool authorized in the King Air 300 Series Maintenance Manual for RVSM static port
measurements may be substituted for this tool. Initialize the tool as follows:
1. Make sure the dial indicator reads negative when the plunger is pressed and positive
when the plunger is free.
2. Place the gauging assembly on a flat surface (gauge block or equivalent.)
3. Ensure the smaller needle is at approximately (.1).
4. Rotate the dial indicator to set the large needle at (0) as shown in Figure 8-4.
G1000 NXi System Maintenance Manual
King Air 300 Series
190-00716-N1
AFT
Figure 8-3, RVSM Critical Region (modified)
EXTERNAL DOUBLER
COVER PLATE
STATIC PORTS
OXYGEN SERVICING DOOR
(RH SIDE ONLY)
AFT
Page 357
Revision 1