System Software And Configuration Load - Garmin G1000 Nxi System Maintenance Manual

Hide thumbs Also See for G1000 Nxi:
Table of Contents

Advertisement

System Software and Configuration Load

System Power Up
Apply power to the G1000 system by connecting external power to the aircraft to energize
the aircraft and avionics electrical busses.
DO NOT RELY ON THE AIRCRAFT BATTERY TO LOAD SOFTWARE. DO NOT USE A
BATTERY CHARGER AS AN EXTERNAL POWER SOURCE DUE TO ELECTRICAL
NOISE IT MAY INJECT IN THE G1000 SYSTEM.
Power loss during a software upgrade may cause a LRU to become corrupted and
unresponsive requiring replacement. Remove power only when told to do so in the
procedure.
MFD & PFD Software Load
1. Open the MFD, PFD 1 (PRI), PFD 1 (SEC), and PFD 2 circuit breakers.
2. Remove Garmin database cards from bottom slots of PFD1, MFD, and PFD2 if present.
3. Insert the software loader card into PFD2 top card slot.
4. Turn on Avionics electrical busses.
5. Close the PFD2 circuit breaker.
6. When the "DO YOU WANT TO UPDATE SYSTEM FILES?" prompt appears, press the
YES softkey.
7. After the new GDU software is loaded to PFD2, a "DO YOU WANT TO UPDATE THE
SPLASH SCREEN?" prompt may appear. If it does, press the NO softkey. The splash
screen will be loaded later in this procedure.
8. When complete, the PFD2 starts in configuration mode displaying the "System Status"
page. Open PFD2 circuit breaker.
9. Remove the loader card from PFD2 and insert it into the top card slot on the MFD.
10. Repeat Steps 5 through 8 for the MFD using the MFD circuit breaker. The MFD does not
have an ENT key, so instead use softkey #12 for ENT when stated above.
11. When MFD update is complete, open the MFD circuit breaker, remove the loader card
from the MFD and insert it into the PFD1 top card slot.
12. Repeat Steps 5 through 8 for PFD1 using the PFD (PRI) circuit breaker. When
complete, leave PFD1 on with the loader card remaining in the top card slot.
13. Start the MFD and PFD2 in configuration mode by pressing and holding the ENT key or
softkey #12 when closing the circuit breakers. Release the key when the words
"INITIALIZING SYSTEM" appear on the screen.
G1000 NXi System Maintenance Manual
King Air 300 Series
190-00716-N1
Page 68
Revision 1

Hide quick links: