Failure Message
MFD1 CONFIG – MFD1
configuration error. Config service
req'd.
PFD 1 CONFIG – PFD 1
configuration error. Config service
req'd.
PFD 2 CONFIG – PFD 2
configuration error. Config service
req'd.
G1000 NXi System Maintenance Manual
King Air 300 Series
190-00716-N1
Cause
A configuration mismatch has
occurred between the display and
the Master Configuration Module.
Solution
Reload the display configuration
files from SD Loader Card.
Reload system configuration files
by pressing the UPDT CFG
softkey on the Configuration
Upload Page in the PFD1 System
Page Group to load configuration
files into the configuration module.
If message persists, check
PFD1 config module wiring for
faults and replace if necessary.
If issue continues, replace
PFD1 master configuration
module.
If problem persists, replace the
display.
NOTE
New Terrain/Obstacle cards, Jeppesen
Aviation Database and other optional
features (i.e. TAWS unlock card) will
need to be replaced if the master
configuration module is changed. The
G1000 System ID number will change
to a new number when installing a new
master config module. The old Terrain
and other databases will no longer
work as they will remain locked to the
old System ID number.