MD 302 Electronic Standby Indicator
Removal:
1. Remove MFD per Section 6.1.
2. Disconnect pitot-static plumbing from the back of the standby airspeed indicator. Take
necessary precautions to prevent foreign object debris from entering the pitot-static lines
during maintenance.
3. Disconnect the electrical connector from the indicator.
4. Use a nut driver to remove the four hex head attachment screws from the front of the
indicator.
5. Remove the indicator.
Reinstallation:
1. Reinstall the electronic standby indicator referencing the Main Instrument Panel
Installation drawing, listed in Table 1-1, for more details.
2. Connect the pitot-static plumbing and electrical connector.
3. Reinstall the MFD.
4. If the Configuration Module was not changed, Configuration Setup is automatic at first
power on and no additional action is required.
5. If a new unit is installed with a new configuration module, Configuration Setup per
Section 3.19 is required.
6. Test MFD per Section 9.1.