Garmin G1000 Nxi System Maintenance Manual page 90

Hide thumbs Also See for G1000 Nxi:
Table of Contents

Advertisement

Push in the FMS knob to activate the curser in the Group field. Rotate the small FMS
knob to highlight "Enable_DualCharts" and press the ENT key to select it.
In the ITEM window, rotate the small FMS knob to highlight "Dual Charts Feature
Enable" and press the ENT key to select it.
Press the Load softkey.
Monitor load progress. Verify software load completes without errors as indicated by the
following:
Green "PASS" in the Configuration column for each item loaded.
"Upload Complete.............COMPLETE" in the summary box.
Press the ENT key to acknowledge the "Upload Complete" box.
Open PFD1 circuit breaker and remove the Dual Charts enablement card.
SurfaceWatch Feature Enablement
Follow this procedure to enable the SurfaceWatch feature.
Insert the SurfaceWatch Enablement card in the top slot of PFD1 and power on PFD1 in
configuration mode.
On PFD1, select the "System Upload" page using the small FMS knob.
Push in the FMS knob to activate the curser in the Group field. Rotate the small FMS
knob to highlight "Enable_SurfaceWatch" and press the ENT key to select it.
In the ITEM window, rotate the small FMS knob to highlight "SurfaceWatch Feature
Enable" and press the ENT key to select it.
Press the Load softkey.
Monitor load progress. Verify software load completes without errors as indicated by the
following:
Green "PASS" in the Configuration column for each item loaded.
"Upload Complete.............COMPLETE" in the summary box.
Press the ENT key to acknowledge the "Upload Complete" box.
Open PFD1 circuit breaker and remove the SurfaceWatch enablement card.
GWX 70 Radar Turbulence Detection Feature Enablement
Follow this procedure to enable the GWX 70 Turbulence Detection feature.
Insert the GWX 70 Turbulence Detection Enablement card in the top slot of PFD1 and
power on PFD1 in configuration mode.
On PFD1, select the "System Upload" page using the small FMS knob.
Push in the FMS knob to activate the curser in the Group field. Rotate the small FMS
knob to highlight "Enable_TD" and press the ENT key to select it.
In the ITEM window, rotate the small FMS knob to highlight "GWX 70 Turbulence
Detection Enable" and press the ENT key to select it.
Press the Load softkey.
G1000 NXi System Maintenance Manual
King Air 300 Series
190-00716-N1
Page 77
Revision 1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents