Symptom
Display flickers
SD card is stuck in GDU
A button/knob/joystick does not
appear to function
Terrain/Obstacle/SafeTaxi does not
display
Display will not track dimmer bus
Keyboard will not track dimmer bus
G1000 NXi System Maintenance Manual
King Air 300 Series
190-00716-N1
Recommended Action
Ensure GDU is receiving power. If a circuit breaker is tripped, determine
source of short before resetting breaker.
Ensure circuit breakers have not failed and power wire connections are secure.
Swap PFD1 and PFD2.
If problem follows unit, replace the display. Please note the position it
failed in (PFD1/2).
If problem does not follow unit, troubleshoot aircraft wiring for fault.
DO NOT insert a screwdriver of any length into the card slot.
DO NOT pry against the overlay.
DO NOT force the SD Card out.
Use a small screwdriver in the groove on the side of the exposed end of the
card to help pull out the card.
Push the card in further to release the card locking mechanism.
Check SD Card for having more than one label. Two or more labels on the
card will cause sticking.
Remove all but one label.
Ensure the SD card is from SanDisk. Use of other SD Cards is not
recommended.
If card was inserted with the label facing to the right, do not attempt to remove.
Return the unit to an authorized repair facility for service.
Go to the GDU TEST page in configuration mode and verify button, knob, or
joystick operates correctly by observing a change in color from red to green in
the button/knob/joystick icon when the button/knob/joystick is pressed. If a
button is stuck, the button icon will be green without pressing the button as
soon as you turn to the GDU TEST page.
If problem is verified, replace GDU.
Allow the system to verify the data in internal memory for approximately five
minutes after power-up.
If a database does not activate, reload the problem database.
Reload GDU configuration files.
If display is a PFD, swap PFD1 and PFD2 to see if problem remains with
display.
 Replace display if condition remains with the same unit.
 If condition remains in original position after swapping displays, check GDU
dimmer input to verify voltage is present.
If display is the MFD, check dimmer input to verify voltage is present.
Replace MFD if dimmer voltage is present.
Page 183
Revision 1