Md 302 Configuration And Sensor Calibration - Garmin G1000 Nxi System Maintenance Manual

Hide thumbs Also See for G1000 Nxi:
Table of Contents

Advertisement

3. Verify that the DATA window shows the following:
Hdg: None:
Hdg Valid Flag
Flag Sense
Hdg Value
Inhibit Line
Antenna Mount
4. Deactivate the cursor.
The DATA window is only updated once every five seconds.

MD 302 Configuration and Sensor Calibration

In the MD 302 Configuration Mode, any changes made to any settings will
NOT be saved until you select ACCEPT CHANGES in the menu prior to
exiting the Configuration Mode.
MD 302 Configuration
1. Open STBY INSTR circuit breaker.
2. Press and hold the MD 302 control knob on the front of the unit.
3. Close STBY INSTR circuit breaker.
4. Release the control knob when the introduction screen appears.
5. In the CONFIGURE MENU, select CONFIGURE DISPLAY by rotating the control knob
to highlight the option and press the control knob to select it.
6. In the CONFIGURE DISPLAY menu, select AIRSPEED UNITS.
7. Select KNOTS.
8. In the CONFIGURE DISPLAY menu, select EXIT.
9. In the CONFIGURE MENU, select CONFIGURE AIRCRAFT.
10. Select PANEL TILT.
G1000 NXi System Maintenance Manual
King Air 300 Series
190-00716-N1
J3-1
Jumper
J3-2
Jumper
No Fla
+invld
J3-4
Open
<aircraft heading>
Off
Bottom
J3-3
Open
NOTE
NOTE
Page 94