Figure 3-12, Mfd Aux - Database Page Db Transfer - Garmin G1000 Nxi System Maintenance Manual

Hide thumbs Also See for G1000 Nxi:
Table of Contents

Advertisement

On the MFD, database verification messages may appear. If so, follow the on-screen
instructions to continue.
Go to the MFD Aux - Databases page to monitor the automatic database update
progress. The new databases will show "Syncing" to the Standby column. After the
databases are synchronized, the system will verify them for use by showing "Verifying" in
the Standby column. After the databases are verified, a cyan double arrow symbol will
appear between the Standby and Active columns to show which databases will be
transferred to Active use on the next power cycle.

Figure 3-12, MFD Aux - Database Page DB Transfer

When all database updates are complete, the Database Update field at the top of the
screen will say, "Restart avionics to activate selected standby databases." If the engines
are not running, a Restart softkey appears at the bottom of the MFD. Press Restart to
cycle power on the displays. If the Restart softkey is not present, turn OFF PFD1, MFD,
and PFD2.
Remove the database update card from the top slot of the MFD.
Turn ON the displays.
The displays may state they are verifying databases at power-up. If so, follow the on-
screen instructions to continue.
G1000 NXi System Maintenance Manual
King Air 300 Series
190-00716-N1
Page 88
Revision 1