4. Select the "SYSTEM UPLOAD" page using the small FMS knob on PFD1.
5. Activate cursor and rotate the small FMS knob to display the drop down menu. Rotate
the large FMS knob to highlight "06) Garmin Transponders" and press ENT key on
PFD1.
6. Rotate the small FMS knob to display the drop down menu. Rotate the large FMS knob
to highlight the installed transponder combination. Press ENT key on PFD1.
7. Press the CLR ALL softkey.
8. Use the large FMS knob to scroll to GTX 1 or GTX 2 whichever was replaced.
9. Highlight the software box and press the ENT key to check the box.
10. Highlight the Configuration box and press the ENT key to check the box.
11. Press "Load" softkey.
12. Monitor load progress. Verify software load completes without errors as indicated by the
following:
Green "PASS" in the Configuration and Software columns for each item loaded.
"Upload Complete............."COMPLETE" in the summary box.
13. Acknowledge the prompt by pushing the ENT key.
14. Deactivate the curser.
15. Scroll to the Configuration Manager page.
16. Press the CNFM CFG softkey.
17. Select ok when prompted to "Confirm configuration as expected configuration"
18. Power cycle the system verify there are no red-Xs or system alerts.
19. If red-Xs or system alerts are present, troubleshoot as necessary using Section 5.
20. If there are no red-Xs or system alerts, continue to Section 7.5.3.
Transponder Configuration
1. If not applied, apply power to the G1000 system and put all displays into config mode.
2. On PFD1, select the AIRCRAFT CONFIGURATION page.
3. For GTX 33 unit replacement only, press the Set GTX # softkey for the unit replaced and
acknowledge the PFD1 prompt by pressing the ENT key. For GTX 3000 units only,
press the SET GTX softkey and acknowledge the PFD1 prompt by pressing the ENT
key. GTX 335R and 345R units automatically save the registration number, no action is
needed for these units.
4. After completing transponder configuration, deactivate the cursor.