Required Tools
The following tools are needed to perform maintenance tasks on G1000 equipment:
Calibrated Milliohm meter, OR
o Agilent 34410A Ammeter or equivalent
o Fluke 187 Voltmeter or equivalent
o Variable DC Power Supply capable of providing 1 amp current
#2 Non-Magnetic Phillips Screwdriver
3/32" Hex tool
Calibrated digital level (Required for AHRS 'Procedure A' Calibration)
Calibrated VHF NAV/COM/ILS ramp tester or equivalent
Calibrated transponder ramp tester or equivalent
Calibrated pitot/static ramp tester
Outdoor line-of-site to GPS satellite signals or GPS indoor repeater
Headset/microphone
Ground Power Unit (Capable of supplying 28 Vdc)
Calibrated Flight Control Cable Tension Meter or equivalent
2 Amp, 24 V, DC Power Supply
Calibrated torque wrench capable of measuring 0 – 70 in/lbs
Standard sockets & wrenches (3/8", 9/16", and 13/16")
Calibrated digital thermometer suitable for measuring ambient temperature
Laptop with RS232 emulation software
M22885/108T8234 extraction tool
An 0.060" 6-Spline wrench