Figure 9-2, PFD Power-up System Annunciations
Allow the displays to initialize for approximately one minute. During normal operation,
this causes the airspeed, altitude, vertical speed, and OAT fields to be invalid during the
first ~40-60 seconds of PFD power-up. After two minutes, verify no Red-X's are present
on both PFDs and the MFD. Examples of potential Red-Xs are shown in Figure 9-2. If
any Red-X's are present, stop and troubleshoot per Section 5. Examples of PFDs with
no Red-X failure indications are shown in Figure 9-3.
G1000 NXi System Maintenance Manual
King Air 300 Series
190-00716-N1
Page 373