9. G1000 System Return to Service Procedure
If a G1000 LRU was replaced, verify the correct LRU software part numbers and versions
against the numbers listed on the General Arrangement drawing listed in Table 1-1.
Perform the following subsection tests to confirm the G1000 system is operating correctly.
Display Test
Apply aircraft power. On the MFD power-up screen in the upper right corner, find the
'King Air B300 Series System XXXX.XX' number. This number is the G1000 System
Software Loader Image version number that was used to install the software to the
system.
Verify that the System Software Version is the same as listed in Table 1 of the 005-
00629-N2 General Arrangement Drawing.
Press the GCU ENT key to acknowledge the 'DEFAULT PROFILE' Crew Profile option
on the MFD (NOTE: The rightmost softkey on the MFD may also be used).
G1000 NXi System Maintenance Manual
King Air 300 Series
190-00716-N1
Figure 9-1, MFD Power Up Page
Page 372
Revision 1