PFD 2 RS-232
Channel
LRU
CHNL 2
GMC 710
G1000 NXi System Maintenance Manual
King Air 300 Series
190-00716-N1
Indicator
Status
Green
PFD2/GMC 710 data path is functioning correctly.
PFD2/GMC 710 data path is not functioning correctly.
•
Verify GMC 710 is powered on.
o If GMC 710 will not power on, remove unit and
Red
•
Load PFD2 and GMC 710 configuration files.
•
Swap PFD2 and PFD1 to confirm if the problem is in
the original PFD2.
o Replace original PFD2 if box turns green after
•
Check the PFD2/GMC 710 interconnect wiring for
faults.
Replace GMC 710 if problem remains.
PFD2/GMC 710 data path functionality is unknown.
Amber
Reload PFD2 configuration file.
verify power and ground are present at the
GMC connector.
If power or ground is not present,
troubleshoot aircraft wiring for faults.
If power and ground are present,
replace GMC 710.
swapping displays.