Toshiba e-STUDIO556 Service Manual page 1222

Multifunctional digital systems
Hide thumbs Also See for e-STUDIO556:

Advertisement

Sub
05/08
Mode
Element
element
05
Adjustmen
Scanner
Scanner
Size detection of
t mode
original
05
Adjustmen
Scanner
RADF
t mode
05
Adjustmen
Printer
Printer
Fine adjustment of
t mode
polygonal motor
rotation speed
05
Adjustmen
Printer
Printer
Fine adjustment of
t mode
polygonal motor
rotation speed
05
Adjustmen
Printer
Image
Adjustment of laser
t mode
writing start position
05
Adjustmen
Printer
Image
Adjustment of laser
t mode
writing start position
05
Adjustmen
Printer
Image
Adjustment of drawer
t mode
sideways deviation
05
Adjustmen
Printer
Image
Adjustment of drawer
t mode
sideways deviation
05
Adjustmen
Printer
Image
Adjustment of drawer
t mode
sideways deviation
e-STUDIO557/657/757/857
Item
Subitem
Code
3237
3350
Adjustment of primary
4000
scanning direction
reproduction ratio
Adjustment of primary
4001
scanning direction
reproduction ratio
Primary scanning
4005
direction
Primary scanning
4006
direction
4018
4018
4018
Sub-
Default
Acceptable
Details
code
value
value
Starting time
64
0-255
adjustment of lamp
lighting
Trailing edge
50
0-100
adjustment of
scanning
PPC
128
0-255
PRT
131
0-255
PPC
128
0-255
PRT
Refer to
0-255
contents
0
1st drawer
128
0-255
1
2nd drawer
128
0-255
2
3rd drawer
128
0-255
6
RAM
Contents
SYS Adjusts the starting time of lamp lighting when the
detection accuracy of dark originals is poor.
Maximum value: 255 (Minimum time + 2040 ms)
Minimum value: 0 (Minimum time)
SYS When the value increases by "1", the trailing edge of
scanned original becomes longer by 0.3 mm at RADF
copying.
When the value decreases by "1", the trailing edge of
scanned original becomes shorter by 0.3 mm at RADF
copying.
* This code is effective when the value of 08-3075 is "1"
(Allowed).
M
When the value increases in increments of "1", the
reproduction ratio of the primary scanning direction
increases as follows:
e-STUDIO557/657: 0.3 mm/step
e-STUDIO757/857: 0.1 mm/step
M
When the value increases in increments of "1", the
reproduction ratio of the primary scanning direction
increases as follows:
e-STUDIO557/657: 0.3 mm/step
e-STUDIO757/857: 0.1 mm/step
M
When the value increases by "1", the writing start
position shifts to the front side by approx. 0.0423 mm.
M
When the value increases by "1", the writing start
position shifts to the front side by approx. 0.0423 mm.
<Default value>
e-STUDIO557/657: 113
e-STUDIO757/857: 123
M
When the value increases by "1", the image shifts
toward the front side by 0.0423 mm.
M
When the value increases by "1", the image shifts
toward the front side by 0.0423 mm.
M
When the value increases by "1", the image shifts
toward the front side by 0.0423 mm.
Proce
Servic
dure
e UI
1
1
1
Yes
1
Yes
1
Yes
1
Yes
4
Yes
4
Yes
4
Yes