Catalytic converter
Apply AREXONS SVITOL TECHNIK SILIKON
SPRAY to the joint between the catalytic
converter and the silencer, leaving the product to
act for a few minutes.
Loosen the Torx clamp (2) fastening the catalytic
converter (A) to the silencer (3).
If present, remove shield (9) by loosening the
indicated screws.
Remove the clamp (4).
Disconnect the two quick connectors indicated from
the bellow (5).
Undo the two nuts indicated fastening the air flow
meter to the air box (6).
Move the air flow meter - motorised throttle body
assembly to one side, without disconnecting
from the electrical system.