2
Click the data to set.
The data, 0.0000 (Not set), shows that user data has not been created yet.
When using user data, be sure to set the value.
When setting 0 as the default, set 0.
3
Set the default value for the data.
Item
Data
4
Enter the comment for the data.
The entered comment will be displayed in the [Comment] column of the User Data processing item.
Item
Comment
5
Repeat steps 2 to 4 to set the user data.
Up to 100 user data (No. 0 to 99) can be set.
6
To exit the User Data Tool, click [Close].
7
Click [Data save] to save the specified user data Set Values (Settings download and upload
tools)
To create a list of the set values for scene data, use the Settings Download and Upload Tools.
With the set value download function, the specified scene data set values can be output to a CSV file.
Different set values in multiple scene data can be easily checked by opening the CSV files in an editor.
(Only data that can be read and written can be downloaded.) The Setting Values Upload Tool allows
you to upload a CSV file with confirmed set values.
A - 38
Set value [Factory default]
−999999999.9999 to 999999999.9999
[0.0000]
Set value [Factory default]
64 characters max.
[Space]
Description
Sets the specified user data value. This sup-
ports multi-lingual.
Refer to 3-2-2 Inputting Text on page 3-7.
Description
Sets the comments for the specified user data.
This supports multi-lingual.
Refer to 3-2-2 Inputting Text on page 3-7.