Omron FH-1 series User Manual page 534

Hide thumbs Also See for FH-1 series:
Table of Contents

Advertisement

Appendices
Edge Level
Indicates the edge color change level (degree of color difference). This level is adjusted if edges cannot
be accurately detected.
Additional Information
The value 0 to 100 for the edge level indicates the edge intensity. It is not related to color differ-
ence in the original images.
• For case of measurement using relative position (%) with regards to width of color difference
The edges are detected in the following manner.
1
Calculate the overall distribution of color difference in the measurement region.
2
Min. color difference value: 0%; Max. color difference value: 100%
3
Locations in which there is an edge level color difference are detected as edges.
• Edge Position
Measurement
region
• Edge Pitch
Example)
100%
20%
0%
20%
100%
• When performing measurement using color difference value
Edge level is set using color difference absolute value.
Measurement region
A - 16
Max. color difference
100%
Edge level
50%
0%
Min. color difference
Measurement area
Edge level
Edge level
1
Noise
50
0
Edge level (absolute value)
Vision System FH/FHV/FZ5 Series User's Manual (Z365)