Omron FH-1 series User Manual page 243

Hide thumbs Also See for FH-1 series:
Table of Contents

Advertisement

Additional Information
In order to perform logging quickly, image files are first saved in the Controller memory (RAM).
The Controller memory (RAM) for saving images is a ring memory.
Refer to A-7 About Number of Logging Images on page A-23.
If power of the Controller is turned OFF or it is restarted, the data saved in the Controller mem-
ory or RAM Disk will be cleared.
Select [Save to memory + file] or [Save to memory + FTP Server] to save them in external stor-
age.
When [Save to memory + file] in [Destination] is selected, set the destination and file names.
Parameter
Folder name
If you select [Save to memory + FTP Server] as a [Destination], configure the setting items
below.
Setting item
IP address
User name
Password
Port number
Connection
method
Folder name
5
Specify the prefix of the image logging file.
Setting item
Prefix
Vision System FH/FHV/FZ5 Series User's Manual (Z365)
Set value [Factory default]
• [RAM Disk]
• Drive name of external
storage device
Set value [Factory default]
a.b.c.d
a: 1 to 223
b: 0 to 255
c: 0 to 255
d: 0 to 255
[1.0.0.0]
[Anonymous]
---
[21]
• [Active]
• Passive
---
Set value [Factory default]
---
6 Performing Measurement and Adjustment
Description
Specify the image file save destination (RAM disk or external
storage). Logged images are saved in the specified save
destination folder. (Maximum number of characters: 128 sin-
gle-byte characters)
Description
Specify the IP address of the destination FTP server.
Connection via a proxy server cannot be made.
Specify the user name which is used for a connection with the
destination FTP server. Use only single-byte alphanumeric
characters and numbers.
Enter the password for a connection with the destination FTP
server.
Enter the port number for a connection with the destination
FTP server.
Select the FTP connection method.
Specify the destination directory of the FTP server. Use the
relative pathname of the destination directory.
Use only single-byte alphanumeric characters and numbers.
Description
Set the prefix for the saved file name. (Maximum number of
characters: 32 single-byte characters)
The set character string is added at the beginning of the
name of the save file. Use only single-byte alphanumeric
characters and numbers.
If a prefix contains a non-supported character, a logging error
is generated when logging is executed.
6
6 - 13

Advertisement

Table of Contents
loading

Table of Contents