Macro Trigger Window (Mdi_Mcrtrigger.dll) - Omron FH-1 series User Manual

Hide thumbs Also See for FH-1 series:
Table of Contents

Advertisement

8 Setting Windows

8-3-20 Macro Trigger Window (MDI_McrTrigger.dll)

Part to call a macro subroutine at a specific timing.
This window part does not have display elements for the main screen.
This function can not be used with the FHV series.
Details that can be set are as follows.
Setting item
Macro
Macro type
Event func.
Measure init.
Scene switching
Important
• Set subroutine name to specify in [Event Func.] in accordance with the following rules.
*+[Single-byte alphabetical character]+[Single-byte alphanumeric character and _ (under-
score)]
Example: *MEASUREDISP
8 - 56
Setting value
[Factory default]
Sets macro to call.
• [Scene Macro]
Sets the macro type to execute.
• IO Macro
Sets the timing.
[Blank]
Specifies the macro subroutine (including *) to execute when
the measurement initialization was executed.
[Blank]
This item is available when [IO Macro] is selected in [Macro
type].
Specifies the macro subroutine (including *) when the scene
switching was performed.
Description