11 What to Do!
Error message
The Logon to Network Server screen is dis-
played.
Although an error message such as the following, is not displayed, the ERROR signal and the ERR
indicator will turn ON.
The STEP signal was input when the
READY signal was turned OFF.
A non-existing parallel command was
entered.
The parallel scene group switch command
was executed when no USB memory was
installed.
(FZ5-L series / FZ5-600 series)
11 - 8
The connection was cut off based on the idling / session time set
on the network logging destination PC.
At the command prompt on the PC, enter the following:
net config server /autodisconnect:-1
Then disable the automatic disconnection setting.
Cause
• Input the STEP signal after the READY signal turns ON.
• Noise is superimposed onto the STEP signal. Keep PLC and FH
• Please enter a correct parallel command.
• Switch the scene group with the USB memory installed.
Troubleshooting
Troubleshooting
series / FZ5 series Sensor Controller away from the noise
source.
Vision System FH/FHV/FZ5 Series User's Manual (Z365)