8 Setting Windows
• Limit Box Setting Region
Setting item
Lower limit
Upper limit
Unit no
Unit label
Data no
[Data reference]
button
Data ident
ident 0
ident 1
Scene variable
System variable
8 - 78
Setting value
[Factory default]
• [Unit data (No.)]
• Unit data (identifier
name)
• System data
• Scene variable
• System variable
0 to Number of units in the
display target scene - 1 [0]
• [Unchecked]
• Checked
0 to 9999999 [0]
Description
Sets the unit specification method for targets for which to carry
out upper/lower limits settings.
The settings details vary depending on specification methods.
Sets when [Unit data (No.)] or [Unit data (ident)] is selected in
the "Lower limit"/"Upper limit".
Use the unit number to specify the unit to be the target for the
upper/lower limit setting.
The units that are registered for the scene that is the target of
the normal dialog box will appear in the combo box.
Select the processing unit to set.
Sets when [Unit data (No.)] or [Unit data (identifier name)] is
selected in the "Lower limit"/"Upper limit".
If using the unit label to specify the unit to be the target for the
upper/lower limit setting, select this, and set the unit label.
Sets when [Unit data (No.)] is selected in the "Lower limit"/
"Upper limit".
Specify the data to be the target for the upper/lower limit set-
tings using the data number.
Enter the data number for the unit that is specified by the target
unit number.
Sets when [Unit data (No.)] is selected in the "Lower limit"/
"Upper limit".
You can select the data number by directly entering it, or you
can enter it with the [Data reference] button.
Click the [Data reference] button to select the target data in the
[Data reference] dialog box.
Sets when [Unit data (ident)] is selected in the "Lower limit"/
"Upper limit".
Use the unit identifier name to specify the unit to be the target
for the upper/lower limit setting.
Sets when [System data] is selected in the "Lower limit"/"Upper
limit".
Specify the system data to be the target for the upper/lower
limit setting using the identifier information 0 and identifier infor-
mation 1.
(Refer to the Vision System FH/FHV/FZ5 Series Macro Cus-
tomize Functions Programming Manual (Cat No. Z367-E1) sys-
tem data list.)
Sets when [Scene variable] is selected in the "Lower limit"/
"Upper limit".
Specify the scene variable to be the target for the upper/lower
limit settings using the scene variable name.
Sets when [System variable] is selected in the "Lower limit"/
"Upper limit".
Specify the system variable to be the target for the upper/lower
limit settings using the system variable name.
Vision System FH/FHV/FZ5 Series User's Manual (Z365)