Setting item
Decimal digits
Max value
Min value
Important
• The limit box setting region sets an upper and lower limit for one data item. Accordingly,
ensure upper and lower and limits for different data are not set.
• If you change the measurement flow after you create a custom dialog box, change the target
unit number to match the edited measurement flow.
• Soft Keyboard Setting Region
Parameter
Data Type
Target Unit No.
Unit label
Target data No.
[Data reference]
button
Vision System FH/FHV/FZ5 Series User's Manual (Z365)
Setting value
[Factory default]
0 to 4
[4]
−999999.9999 to
999999.9999
[999999.9999]
−999999.9999 to
999999.9999
[−999999.9999]
Set value
[Factory default]
• [Unit data (No.)]
• Unit data (ident)
• System data
• Scene variable
• System variable
0 to Number of units in the
display target scene - 1 [0]
• [Unchecked]
• Checked
0 to 9999999 [0]
Description
Enter the number of digits after the decimal place that can be
entered by the upper/lower limit setting.
Enter the maximum value that can be entered with the upper/
lower limit setting.
Enter the minimum value that can be entered with the upper/
lower limit setting.
Description
Sets the unit specification method for targets for which to carry
out character string settings.
The settings details vary depending on specification methods.
Sets when [Unit data (No.)] or [Unit data (ident)] is selected in
the "Data Type".
Use the unit number to specify the unit to be the target for the
character string setting.
The units that are registered for the scene that is the target of
the normal dialog box will appear in the combo box.
Select the processing unit to set.
Sets when [Unit data (No.)] or [Unit data (ident)] is selected in
the "Data Type".
If using the unit label to specify the unit to be the target for the
character string setting, select this, and set the unit label.
Sets when [Unit data (No.)] is selected in the "Data Type".
Specify the data to be the target for the character string setting
using the data number.
Enter the data number for the unit that is specified by the target
unit number.
Sets when [Unit data (No.)] is selected in the "Data Type".
You can select the data number by directly entering it, or you
can enter it with the [Data reference] button.
Click the [Data reference] button to select the target data in the
[Data reference] dialog box.
8 Setting Windows
8 - 79