6 Performing Measurement and Adjustment
4
Set the logged image save destination.
Parameter
Destination
Important
• Logging images saved in the Controller memory are overwritten starting with the oldest
image if the upper limit for the number of save images is exceeded. Refer to A-7 About Num-
ber of Logging Images on page A-23.
• The data saved in the Controller memory or RAM disk is deleted when the Controller is
restarted.
• If an external storage is specified as the save destination, the processing time may be longer
or may fluctuate. Be sure to check functionality thoroughly before starting operation.
• If images and data are logged to a network drive, the use of the multi-input function and other
heavy measurement loads on the Controller may slow down communications and cause log-
ging errors.
In this case, set the measurement Takt time so that there is some leeway.
• [Save to memory + FTP Server] can be used with FH/FHV/FZ5-800/1100/1200 series only. It
can not be used with FZ5-600/FZ5-L series.
• There are below limitations for [Save to memory + FTP Server] function.
• Connection via a proxy server cannot be made.
• Some servers will not generate logging errors even if save memory capacity is insufficient.
• In the case of where a recognition delay of external storage has occurred at start-up of the
Sensor Controller depending on types or number of connections of external storage, logging
may fail in a measurement executed just after start-up of the Sensor Controller.
Use the Device Information Storage Tool to execute logging to external storage.
Refer to 3-6-2 Device Information Storage Tool on page 3-35.
• In the case where a connection with an FTP server needs longer time at startup of the Sen-
sor Controller depending on types of FTP server, logging may fail just after start-up of the
Sensor Controller.
In that case, start a measurement after sufficient time passed after the Sensor Controller
start-up according to your usage environment.
6 - 12
Set value
[Factory default]
[Save to memory]
Save to memory + file
[Save to memory + FTP
Server]
Description
Saves data to the Controller memory (RAM).
Images that are saved to the Controller memory (RAM) are
saved as files to external storage or to the RAM disk in the
Controller.
Images that are saved to the Controller memory (RAM) are
saved as files to the FTP server.
Vision System FH/FHV/FZ5 Series User's Manual (Z365)