Omron FH-1 series User Manual page 375

Hide thumbs Also See for FH-1 series:
Table of Contents

Advertisement

Radio Button Setting Region
Parameter
Data Type
Target Unit No.
Unit label
Target data No.
[Data reference]
button
Data ident
ident 0
ident 1
Scene variable
System variable
Value
Important
If you change the measurement flow after you create a custom dialog box, change the target
unit number to match the edited measurement flow.
Vision System FH/FHV/FZ5 Series User's Manual (Z365)
Set value
[Factory default]
• [Unit data (No.)]
• Unit data (ident)
• System data
• Scene variable
• System variable
0 to Number of units in the
display target scene - 1 [0]
• [Unchecked]
• Checked
0 to 9999999 [0]
0 to 9999999 [0]
Description
Sets the unit specification method for targets for which to carry
out radio button settings.
The settings details vary depending on specification methods.
Sets when [Unit data (No.)] or [Unit data (ident)] is selected in
the "Data Type".
Use the unit number to specify the unit to be the target for the
radio button setting.
The units that are registered for the scene that is the target of
the normal dialog box will appear in the combo box.
Select the processing unit to set.
Sets when [Unit data (No.)] or [Unit data (ident)] is selected in
the "Data Type".
If using the unit label to specify the unit to be the target for the
radio button setting, select this and set the unit label.
Sets when [Unit data (No.)] is selected in the "Data Type".
Specify the data to be the target for the radio button setting
using the data number.
Enter the data number for the unit that is specified by the target
unit number.
Sets when [Unit data (No.)] is selected in the "Data Type".
You can select the data number by directly entering it, or you
can enter it with the [Data reference] button.
Click the [Data reference] button to select the target data in the
[Data reference] dialog box.
Sets when [Unit data (ident)] is selected in the "Data Type".
Use the unit data (identifier name) to specify the unit to be the
target for the radio button setting.
Sets when [System data] is selected in the "Data Type".
Specify the system data to be the target for the radio button
setting using the identifier information 0 and identifier informa-
tion 1.
(Refer to the Vision System FH/FHV/FZ5 Series Macro Cus-
tomize Functions Programming Manual (Cat No. Z367-E1) sys-
tem data list.)
Sets when [Scene variable] is selected in the "Data Type".
Specify the scene variable to be the target for the radio button
setting using the scene variable name.
Sets when [System variable] is selected in the "Data Type".
Specify the system variable to be the target for the radio button
setting using the system variable name.
Enters the numeric value to set in the target data when the
radio button is selected.
The numeric value to be set here is the set value for that
selected radio button that is applied to the data for the target
data number when the operator changes the radio button
selection on the actual user dialog box.
8 Setting Windows
8 - 81
8

Advertisement

Table of Contents
loading

Table of Contents