Label Setting Region
Parameter
Data Type
Target unit No.
Unit label
Target data No.
[Data reference]
button
Data ident
Ident 0
Ident 1
Scene variable
System variable
Important
If you change the measurement flow after you create a custom dialog box, change the target
unit number to match the edited measurement flow.
Vision System FH/FHV/FZ5 Series User's Manual (Z365)
Set value
[Factory default]
• [Unit data (No)]
• Unit data (ident)
• System data
• Scene variable
• System variable
0 to No. of units in the dis-
play target scene – 1 [0]
• [Unchecked]
• Checked
0 to 9999999 [0]
Description
Sets the unit specification method for targets for which to carry
out the label setting. The setting details vary depending on the
specification method. Setting of title The place where "{0}" in
character string is the data notation set by data type.
This is available when [Unit data (No.)] or [Unit data (ident)] is
selected in the "Data Type".
Specifies the unit to be the target for the label setting.
The units that are registered for the scene that is the target of
the normal dialog box will appear in the combo box.
Select the processing unit to set.
This is available when [Unit data (No.)] or [Unit data (ident)] is
selected in the "Data Type".
When using the unit label to specify the unit to be the target for
the label setting, select this and set the unit label.
This is available when [Unit data (No.)] is selected in the "Data
Type".
Specifies the data to be the target for the label setting.
Enter the data number for the unit that is specified by the "Tar-
get unit No.".
This is available when [Unit data (No.)] is selected in the "Data
Type".
You can select the data number directly to enter it, or you can
enter it with the [Data reference] button.
Click the [Data reference] button to select the target data in the
[Data reference] dialog box.
Sets when [Unit data (ident)] is selected in the "Data Type".
Use the unit data (identifier name) to specify the unit to be the
target for the label setting.
These are available when [System data] is selected in the
"Data Type".
Specifies the system data to be the target for the label setting
using the identifier information 0 and identifier information 1.
(Refer to Vision System FH/FZ5 Series Macro Customize
Functions Programming Manual (Cat No. Z367-E1) system
data list.)
This is available when [Scene variable)] is selected in the "Data
Type".
Specifies the scene variable to be the target for the label set-
ting using the scene variable name.
This is available when [System variable)] is selected in the
"Data Type".
Specifies the system variable to be the target for the label set-
ting using the system variable name.