Omron FH-1 series User Manual page 355

Hide thumbs Also See for FH-1 series:
Table of Contents

Advertisement

Setting item
Data ident/Variable
Data
BUSY ON
Operation ident
Status
Enable
Selected
Front/Back
Control
Control ID
Text & Font Setting
Text Setting
Vision System FH/FHV/FZ5 Series User's Manual (Z365)
Setting value
[Factory default]
[Blank]
Sets the identifier name for the data to set using up to 32 char-
acters.
The setting contents vary depending on [Data Type].
1. Unit data: External reference number or identifier name
2. Scene variable/System variable: Variable name
3. System data/Global data: Identifier name
Specify "gosub" when calling a macro subroutine and spec-
ify "direct" for direct execution.
[Blank]
Specifies the numerical value data or character string to set.
Specify using up to 32 characters the name of the subroutine
(including*) if executing a macro subroutine.
For direct execution, specify the macro program.
• [Unchecked]
Check the box to turn on BUSY during data setting.
• Checked
Sets when controlling the button operation with security.
Set the identifier name to write to Message\FZ-SecuritySet-
ting_xxx.msg.
Sets the status for the data setting button.
[Blank]
Specifies the variable to store the data setting button status
from the variable assignment window.
However, only the scene variable or system variable can be
specified.
Refer to Assigning variables on page 5-61.
The variable value is:
0:
Other than 0: Set the data setting button to enabled state.
[Blank]
Specifies the variable to store the data setting button status
from the variable assignment window.
However, only the scene variable or system variable can be
specified.
Refer to Assigning variables on page 5-61.
The variable value is:
0:
Other than 0: Set the data setting button to selection state.
[Blank]
Specifies the variable to store the data setting button status
from the variable assignment window.
However, only the scene variable or system variable can be
specified.
Refer to Assigning variables on page 5-61.
The variable value is:
Positive: Move window to the front.
Negative: Move window to the back.
0:
Sets when changing the status for the numerical value input
window using a macro.
0 to 999 [0]
The ID used to identify the operation target when using the
macro RaiseOptionEvent relationship to carry out operations.
Displays the setting contents for [Text Setting], [Font Setting],
and [Color Setting].
Sets character data to display.
8 Setting Windows
Description
Set the data setting button to disabled state.
Set the data setting button to normal state.
Do not move the window.
8
8 - 61

Advertisement

Table of Contents
loading

Table of Contents