6 Performing Measurement and Adjustment
10
Click [Data Logging].
The data format is set with the Data Logging processing item.
Parameter
Data logging
11
Set the logged data save destination.
Parameter
Folder name
12
Click [Apply].
Important
• The data saved in the Controller memory or RAM disk is deleted when the Controller is
restarted.
• If external storage is specified as the save destination, the processing time may be longer or
may fluctuate. Be sure to check functionality thoroughly before starting operation.
• If images and data are logged to a network drive, the use of the multi-input function and other
heavy measurement loads on the Controller may slow down communications and cause log-
ging errors. In this case, set the measurement takt time so that there is some leeway.
6 - 18
Set value
[Factory default]
[None]
Only NG
All
Set value
[Factory default]
• [RAM Disk]
• USBDisk
Description
Measurement data is not saved.
Measurement data is saved when an NG error occurs in a unit
before a [Data Logging] unit. If an NG error occurs after the
[Data Logging] processing unit, data logging is not performed.
All measurement data is saved.
Description
The data is saved in the specified destination folder (RAM disk
or USB disk). Set the file name with the [Data Logging] process-
ing unit. (Maximum number of characters: 128 single-byte char-
acters)