8 Setting Windows
Setting item
Macro specification
Macro Type
Unit Name
Format Setting
Row Count
Col. Count
8 - 42
Setting value
[Factory default]
Sets macro containing variables to display.
• Macro Unit
• [Scene Macro]
Sets which macro variables to display.
• I/O Macro
Sets this when [Macro Unit] is selected in [Macro Type]. Spec-
ify the macro unit with a unit number or a unit label character
0 to 32 characters
string.
[0]
Only single-byte alphanumeric characters as well as "_&#$@"
can be input.
Sets table display related issues.
Specifies the variable name for the macro storing the table row
count using up to 32 characters.
However, only those integer type variables within the macro
selected in [Macro Type] can be selected.
If any of the following conditions are met, then regardless of the
settings, the row count will be 1.
[Blank]
• Variable is not specified.
1 to 128
• Specified variable does not exist.
• Value stored in the variable is other than numerical value.
If any of the following conditions are met, then regardless of the
settings, the row count will be 128.
• Value stored in the variable is 129 or higher.
Specifies the variable name for the macro storing the table col-
umn count using up to 32 characters.
However, only those integer type variables within the macro
selected in [Macro Type] can be selected.
The range of the column count for the table is from 1 to 32 col-
umns.
If any of the following conditions are met, then regardless of the
[Blank]
settings, the column count will be 1.
• Variable is not specified.
• Specified variable does not exist.
• Value stored in the variable is other than numerical value.
If any of the following conditions are met, then regardless of the
settings, the column count will be 32.
• Value stored in the variable is 33 or higher.
Description
Vision System FH/FHV/FZ5 Series User's Manual (Z365)