Switching Processing Unit Measurement ON/OFF
The measurement function can be enabled and disabled per processing unit. A processing unit that the
function has been disabled cannot perform the measurement until the function is enabled.
1
Display the Edit flow tab screen for the scene to edit.
For more details, refer to 5-5-1 Edit Flow Screen on page 5-14.
2
On the Edit flow tab screen, select a processing unit on the Unit list (flow) that its measurement
function is to be enabled or disabled.
3
In the Edit flow button area, click
An "X" is marked on the selected processing unit icon. That means that the measurement func-
tion of it is disabled. Clicking
Important
Be sure to enable the measurement function for the image input processing unit with the unit
No. 0 before use.
Additional Information
The following operation also enables or disables the measurement function for a processing unit.
• Click [Measurement ON/OFF] from [Edit flow] in the Menu bar.
• Right-click a processing unit on the Unit list (flow) and then click [Measurement ON/OFF] on
the displayed shortcut menu.
Additional Information
• Turning on or turning off the measurement function for a folder, a parallelization processing
unit, or a parallelized task processing unit turns on or off the measurement for all processing
units for the folder, the parallelization processing unit, or the parallelized task processing unit.
• When [ON] is set for [Parallel Execute] in [Operation mode setting] in the system settings,
turning the measurement function setting ON/OFF for a processing unit may greatly change
the processing time. In this case, use parallelization processing items to parallelize the mea-
surement flow instead of using automatic parallel processing. For details, refer to 4-4-2 Par-
allel Processing on page 4-29.
• When the measurement function for a processing unit in a conditional branch destination has
been disabled, the measurement will be performed from a processing unit set to on in the fol-
lowing branch destination processing units.
• Overall judgement result of the processing units that are set in the folder is displayed in the
folder unit. However, if a Conditional branch is set to branch outside the folder, the overall
judgement result of the processing units set in the folder unit will always display as OK.
Vision System FH/FHV/FZ5 Series User's Manual (Z365)
5 Creating Measurement Scenes
[Measurement ON/OFF].
toggles the ON/OFF state of the measurement function.